Dose Area Product Measurement Device 5400481-R

5400481-R
X-Ray
GE HealthCare
Exchange - Return Defective
Add to Wish List
Login To Shop
Login To Shop
Please select date
Second Opinion Approval Needed

Enter your approval number and submit to add item(s) to cart.

Approval Number

Please enter approval number

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without the
approval number, GE will contact you before your order
can be confirmed for shipment.

Second Opinion Approval Needed

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


Features

  • Integrated display
  • Interface to printer or secondary display
  • Chamber power options
  • Display powered by power supply

Other Buying Options


Product Overview

A DAP meter measures the incident air kerma area product (DAP) the recording of the DAP value is required for comparison with diagnostic reference levels in radiology and fluoroscopy. It provides a wide range of rectangular light transparent DAP chambers suitable for most of the X-Ray systems. The rectangular light transparent DAP meters are slid into the accessory rails at light field collimators, whereas in C-arm machines the DAP chamber is usually installed inside the housing of the X-Ray source. DAP meters with display (stand-alone systems) can be used for the retrofitting of existing X-Ray systems. The wireless configuration, using an independent battery power supply and an integrated display unit, or alternatively, a wireless data transfer to an external display unit makes installation very easy. Wired configurations are also possible. Most modern X-Ray systems are equipped with a built-in DAP meter. In this case the measured values are directly linked to the digital X-Ray image. The standard VacuDAP factory calibration is done at 70 kV with a tube filtration of 2.5 mm Aland without additional absorbers. The GE product is an innovation which fits well into versatile customer needs. The part is diligently designed for superior performance and reliability. It is securely packed inside a high quality packing box to avoid physical damage during transit and labeled with details about the product, Quality Assurance (QA) seal and shipment details.